UNI-8084


UNI-8084 is a two-component, 100% solids, V.O.C. compliant, aliphatic polyaspartic developed for UV stable floor topcoats. It provides outstanding appearance, superior chemical, UV, and solvent resistance. It exhibits excellent physical properties. This system complies with the Canadian Food Inspection Agency (C.F.I.A.).
DESCRIPTION


■ Marine protection for fiberglass, steel, concrete or wood
■ UV-stable top coat
■ Aircraft hangar floors
■ Low temperature equipment
■ Maintenance facilities
■ Offshore platforms
■ Industrial shop floors
■ Car washes or wash bays
■ Secondary Containment
■ Cooling towers
■ Bridges
■ Wastewater treatment applications
PRIMARY APPLICATIONS
■ Long pot life (90 min to 100 min)
■ Displays fast cure times with excellent adhesion
■ Superior chemical resistance
■ Superior weather and abrasion resistance
■ Non yellowing and good gloss retention
■ Easy to mix 1:1 ratio by volume
■ Emits virtually no odors and can be applied indoors
■ Excellent adhesive properties, allowing application on other firm and hard coating, as well as a good bond to the substrate
■ V.O.C. compliant in all 50 states and Canada
ADVANTAGES

*Please note, that the indicated mileage is calculated for flat surfaces. A porous or imperfect surface will require more material in order to cover the same surface.


Old Concrete
Concrete surface must be cleaned and mechanically prepared using shotblasting, sand blasting, and/or diamond grinding. All oils, sealers, curing agents, waxes and fats must be removed prior to product application. Do not apply onto wet substrates. Chloride, moisture, and pH levels should be checked prior to application. Strongly recommended to use primer (SCI-100) prior to application of UNI-8084. All cracks and substrate imperfections should be filled and repaired prior to application.

New Concrete
New concrete should be allowed to cure for a minimum of 30 days. Compression resistance of concrete must be at least 25 MPa (3625 lbs./inch2) after 28 days and traction resistance must be at least 1,5 MPa (218 lbs./inch2). Shotblasting, sand blasting, and/or diamond grinding is required to remove the surface laitance that appears during the concrete finishing and curing process. UNI-100 primer is recommended to be used to seal porous concrete surfaces prior to application. All cracks and substrate imperfections should be filled and repaired prior to application.
Surface Preparation


Materials should be pre-conditioned to a minimum of 15°C (50°F) prior to use. Thoroughly mix each component separately using paddle mixers and a drill for a minimum of 2 minutes to place the solids content evenly in suspension. Pour component B into component A using the proper mixing ratio of 1A:1B by volume. Mix both components for at least 3 minutes using a drill at low revolution (300 to 450 rpm) to reduce trapping of air. While mixing, scrape bottom and walls of container at least once to ensure a homogeneous mix. Only prepare quantity that may be applied during pot life of mixture.
MIXING


Apply mixed product on the prepared surface tightly (thin film) using a rubber rake and pass a roller to obtain a uniform coating. Avoid creating puddles.
APPLICATION


Clean all application equipment with a specified cleaner. Once the material hardens it can only be removed mechanically. If the product splatters, wash thoroughly with hot soapy water.
CLEANING


Subsequent overlaps must be applied when primer is still wet or tacky. If primer has dried, reprime. Porous substrates may require multiple priming.
OVERLAPS


Sprinkle the primed area lightly with aggregate to provide better footing.
SUGGESTIONS


■ Minimum/Maximum temperature of substrate: 15°C / 30°C (59°F / 86°F).
■ Maximum relative humidity during application and curing: 85%.
■ Humidity content of substrate must be < 4% when coating is applied.
■ Do not apply on porous surfaces where a transfer of humidity may occur during application.
■ Protect from humidity, condensation and contact with water during the 24-hour initial curing period.
RESTRICTIONS


In case of skin contact, wash with water and soap. In case of eye contact, immediately rinse with wate for at least 15 minutes. Consult a physician. For respiratory irritations, move affected person outdoors to fresh air. Remove contaminated clothes and wash before reuse. Components A and B contain toxic ingredients. Prolonged contact of this product with the skin is susceptible to provoke irritation. Avoid eye contact. Contact with product may cause severe burns. Avoid breathing vapors released from this product. This product is a strong sensitizer. Wear safety glasses and chemical resistant gloves. A breathing apparatus filtering organic vapors approved by the NIOSH/MSHAis recommended. Always work in a properly ventilated area.

*Consult the material safety data sheet for further information.*
HEALTH AND SAFETY


All statements, recommendations and technical information contained in this document are accurate to the best knowledge of UNIFLEX FLOOR COATINGS. The data relates only to the specific material designated herein. It may not be valid if used in combination with any other materials. It is the users’ responsibility to verify suitability of this information for their own particular use, and to test this product before use. UNIFLEX FLOOR COATINGS. assumes no legal responsibility for use upon these data. UNIFLEX FLOOR COATINGS. assumes no legal responsibility for any direct, indirect, consequential, economic, or any other damage except to replace the product or refund the purchase price as set out in the purchase agreement.
‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎‎‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎‎‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎ ‎‎ ‎ ‎
IMPORTANT NOTICE